Pattress Models EI 127 & EI 127R
For use only with EI 140, 141, 144, 145, 146, 161, 161R,
164, 166, 166R Easi-Fit Smoke/Heat Alarms
The Smoke/Heat Alarm is mounted on the EI 127 & EI 127R.
The EI 127 pattress facilitates installation of bulky wiring and conduits.
The EI 127R has an additional socket for connecting to the R spade termi-
nal on the EI161R or EI 166R. This can be used for remote test & hush or
manual call points.
WARNING: This pattress must only be used with one of the above smoke
alarms as per these instructions - otherwise the unit will not comply with
the mandatory safety regulations.
Installation
WARNING: First disconnect the mains from the circuit to be used.
1.Choose a mounting position following the siting instructions in the
Smoke/Heat Alarm leaflet. Where the incoming wiring is on the surface of
the ceiling, the appropriately sized ducting/conduit must be chosen to
mate with the unit. Use a sharp knife to remove material from the selected
knockout, making sure that there is no gap when mated with ducting / con-
duit. There are three knockouts – two on the sidewall and one on the rear.
Figure 1
CONDUIT
FOR EI161R/166R
REMOTE CONTROL ONLY
CONNECT TO SMOKE ALARM
MOUNTING PLATE TERMINALS
- EARTH (IF PRESENT)
- NEUTRAL
N
IC - INTERCONNECT
L
- LIVE
R
KNOCKOUT
KNOCKOUT
L
IC
N
FOR MOUNTING PLATE
|
Ego Technology Clock Radio 4000 Plus User Manual
Electro Voice Music Mixer BK Series User Manual
Extron electronic Switch VTG 150 User Manual
Fagor America Electric Pressure Cooker 918010051 User Manual
Friedrich Air Conditioner 9359944065 User Manual
Fundex Games Board Games Cribbage Premium Wood Cabinet User Manual
Furuno Marine RADAR FR 7010D User Manual
GE Microwave Oven CVM2072 User Manual
GE Toaster 168989 User Manual
GE Water Heater GEH50DEED User Manual